PET (Positron Emission Tomography) facilities. Based on the revolutionary RFI Linac Structure, this unit offers higher isotope production rates together with lower acquisition, installation, shielding, operation, and maintenance costs than other known alternatives. While still under development, these projections are based on well-established accelerator development techniques.

|
Features:
ECR Microwave Ion Source
Einzel Lens LEBT
RFQ Linac to 0.75 MeV
RFI Linac to 12 MeV
Resonantly Coupled Linacs
Single Rf Power Drive Point
Tetrode Rf Power System
|
|
Parameters:
Beam Particle
Energy
Rf Frequency
Beam Current (peak)
(average)
Beam Duty Factor
Pulse Length
Repetition Rate
Rf Power (peak)
(average)
|
Proton
12 MeV
200 MHz
20 mA
400 micro Amps
2.0 %
20 microseconds
1000 Hz
700 kW
14 kW |
|
Packaging (Linac Unit):
Length
Width
Height (beam line)
Weight |
4.5 m
0.7 m
1.2 m
1000 kg |
Packaging (RF Power):
Utilities:
Electrical Power
Accelerator Cooling
Target Cooling |
30 kVA
9.2 kW
4.8 kW |
Target Options:
One-to-Three Targets
Simultaneous Irradiation |
.
. |
|
|